Efficiency

Over 60 scientific studies and clinical tests; around 100 microorganisms

Time to Reduce Pathogens by 3–4 log (99.9–99.99%)
 Direct Distance to Surface in Meters1
MicroorganismTime2 to Reduce Microorganisms Population by 3-4 log in Minutes
 3log 4log
 2m3m4m 2m3m4m
Pseudomonas aeruginosa 0.50.91.5 0.61.22
Acinetobacter baumanni0.50.91.5 0.61.22
Methicillin-resistant Staphylococcus aureus (MRSA)0.50.91.5 0.61.22
Vancomycin-resistant enterococcus (VRE)0.51.12 0.61.42.6
Influenza A1.536 248
Clostridium difficile spores (C.diff)41018 61224
_____________

1 – Horizontal distance from Yanex Antibacterial System to target surface.
2 – Time required to reduce microorganisms' population by 3 log and 4 log is based on the dosage determined by laboratory research.

Time to Reduce Microorganisms' Population by 3–4 log (99.9–99.99%) in the air of a 100 m3 room
MicroorganismTime to Reduce Microorganisms by 3–4 log in Minutes
Bacteria 
Pseudomonas aeruginosa 1.7
Methicillin-resistant Staphylococcus aureus (MRSA)1.5
Vancomycin-resistant enterococcus (VRE)1.8
Escherichia coli1.2
Kl. pneumoniae1.7
Viruses 
Adenovirus6.5
Hepatitis C5.8
Influenza A2.4
Poliovirus2
Fungi 
Aspergillus fumigatus6.2
Candida albicans3.5
Aspergillus niger10
Spores 
Bacillus cereus2
Bacillus subtilis4.5